Normal operation
• Generating pressure: Pressure lower
than switch-on pressure, compressor gen-
erates pressure.
• No-load operation: Pressure greater
than
switch-off
switches to no-load operation, delay time
is displayed.
• Setpoint pressure reached: Delay time
elapsed and pressure not lower than
switch-on
pressure,
switched off.
For variant AM x-10 E1 y DK z:
9.3
With compressed air cold dryer
see Figs. 2a, 2b
1. Fold up safety bar (SB).
2. Push slide (S) slowly inwards so that
compressed air is slowly applied to the
compressed air cold dryer.
10 Maintenance
Interval / No later
than
Daily / --
Weekly / every 50 h
Every 1,500 h
4
pressure,
compressor
compressor
Tasks
Check indicator lamps and (error) messages
Checking the oil level
Check compressor for oil leaks
Drain condensate from compressed air vessel
Replace air filter
Clean outside of oil/air cooler
Clean inside of compressor
Check V-belt tension
3. Important: Fold down safety bar (SB)
for locking slide.
9.4
Without compressed air cold dryer
see Figs. 2b, 2c
1. Fold up safety bar (SB).
2. Pull slide (S) slowly outwards.
3. Important: Fold down safety bar (SB)
for locking slide.
9.5
AM x-10 E1 180 (DX z)
Standard operation using both vessels:
• All ball valves (ball valves 1 to 4, items 25
to 28) are open.
• Ball valves at condensate drainage point 1
(item 10) and condensate drainage point 2
(item 11) are open.
• Ball valve at condensate drainage point 3
(item 12) is closed, only opened to drain
condensate.
Operation using vessel 1 only:
• Ball valve 1 (item 25) and ball valve 4
(item 26) are open.
• Ball valve 2 (item 27) and ball valve 3
(item 28) are closed.
is
• Ball valve at condensate drainage point 1 is
open.
• Ball valve at condensate drainage point 2 is
closed.
• Ball valve at condensate drainage point 3 is
closed, only opened to drain condensate.
Operation using vessel 2 only:
• Ball valves 2 and 3 are open.
• Ball valves 1 and 4 are closed.
• Ball valve at condensate drainage point 2 is
open.
• Ball valve at condensate drainage point 3 is
closed, only opened to drain condensate.
See chap.
10.1
10.3
10.4
10.5
10.6
10.7
10.8
10.9