     Output Polarity Management
This section is used to program the standby polarity for Open Collector outputs OC1, OC2, and OC3 (Open Collector
output OC4 is reserved and Normally Closed) as follows:
   
   
where <Output no.> is the number of the output being programmed (from
     Output Caller Recognition Enable
In this section you can link the activation of outputs with calls from certain telephone numbers in the phone book. To
activate outputs with Caller ID, program the telephone number in the section "Phone Book Management" (see the
Parameters Management section). The output is activated at "cost-free" as the Telephone Dialler, after identifying the
caller, activates the output and the caller can end the call before the Dialler answers. To program this feature, type the
following keypad sequence:
where <Output no.> is the number of the output being programmed (from
positions of the telephone numbers saved in the phone book (1 to 9 positions can be specified).
     To cancel the setting for an output, do not input a telephone number.
     Only outputs OC1, OC2, and OC3 can be activated by caller recognition.
     Confirm Output Activation Enable
This section is used to program the sending of a confirmation message when the output is activated. If this option is
programmed, when an output is successfully activated, the user will receive confirmation. Confirmation takes the following
form:
– a tone if output activation takes place through caller ID.
– a text message containing the same command received by the BTEL-3G if the output is activated by a text message.
To enable or disable, type the following keypad sequence:
Available Networks
     For this test the a gereric valid SIM card must be inserted in the SIM card slot.
This section covers testing reception at the chosen location for installation, in order to identify the operator with the best
coverage. To verify, press
the operators with reception (see the table on page 4 or consult the table at the website http://en.wikipedia.org/wiki/Mobile
Network Code) and after that the strength of the signal tested (low, medium, good, excellent).
     During this test, the 3 GREEN LED's shown the signal strenght with operator of the SIM used to do the
test.
Management Installer Code
The factory default Installer PIN is 11111. To change it, type the following keypad sequence:
where <New PIN> is a number of 5 digits.
     The PIN's typed must be identical, and must be different from the user PIN, or you will be asked to
retype the PIN.
16
<Output no.>
(set as Normally Open - Factory default setting)
<Output no.>
(set as Normally Closed)
   
<Output no.><Telephone Numbers>
   
<Output no.>
   
<Output no.>
. After waiting for approximately 15 seconds, a voice message will begin listing the codes of
<New PIN><Repeat New PIN>
to
).
to
) while <Telephone Numbers> are the
(to Enable)
(to Disable - Factory default setting)