REMOTE PROGRAMMING BY TEXT MESSAGE
The dialler's features allow you to program one or more preset telephone numbers to which text messages will be sent
when specific events take place:
 Any alarm signals on one or more of the 4 inputs.
 Low Battery Test. 2 text messages can be programmed, one for malfunctions and one for resetting.
 Periodic sending of a text message at programmed intervals.
 Sending a text message to check the remaining credit.
Programing is performed by means the following text messages.
LED
blinks three times when the BTEL-3G receives a valid programming SMS.
Input Activation
The BTEL-3G can send a text message to the numbers in the phone book when an event activating the inputs takes
place. To do this, send a programming text message in the following format:
#Installer PIN#INA#Input#Receiving Numbers#Message Text#
where the following are enclosed by # signs:
 Installer PIN; a numeric code of 5 digits (from 00000 to 99999).The factory default installer PIN is 11111.
 INA; the command text that programs the activation of inputs.
 Input; identifies the input (IN1, IN2, IN3, IN4 which correspond to inputs L1, L2, L3, and L4).
 Recipient Number; position of the telephone number in the phone book (see "Paramaters Management->Phone
Book Management "). To send the text message to multiple numbers in the phone book, separate the numbers with
a comma (for example "2,3,5" sends the text message to the telephone numbers stored under numbers 2, 3, and 5).
 Message Text ; type the text message to send (maximum 100 characters).To disable sending of the message not
type the text.
Input Deactivation
The BTEL-3G can send a text message to the numbers in the phone book when an event deactivating the inputs takes
place. To do this, send a programming text message in the following format:
#Installer PIN#IND#Input#Receiving Numbers#Message Text#
where the following are enclosed by # signs:
 Installer PIN; a numeric code of 5 digits (from 00000 to 99999).The factory default installer PIN is 11111.
 IND; the command text that programs the deactivation of inputs.
 Input; identifies the input (IN1, IN2, IN3, IN4 which correspond to inputs L1, L2, L3, and L4).
 Recipient Number; position of the telephone number in the phone book (see "Paramaters Management->Phone
Book Management "). To send the text message to multiple numbers in the phone book, separate the numbers with
a comma (for example "2,3,5" sends the text message to the telephone numbers stored under numbers 2, 3, and 5).
 Message Text ; type the text message to send (maximum 100 characters).To disable sending of the message not
type the text.
Low Battery Power Message
When battery power is low, a text message can be sent to a preset telephone number. To do this, send a programming
text message in the following format:
#Installer PIN#BAT#Receiving Number#Low Battery Power Text#Battery Reset Text#Enable#
where the following are enclosed by # signs:
 Installer PIN; a numeric code of 5 digits (from 00000 to 99999).The factory default installer PIN is 11111.
 BAT; the program command to send a message informing that the battery power is low.
 Recipient Number: type the phone number of the recipient (not its position in the phone book). The telephone
number may also be a number not found in the phone book.
 Low Battery Power Text ; type the text message informing the recipient that the Battery Power is Low (maximum
50 characters).
 Reset Text ; type the text message to be sent to notify that the Battery Has Been Reset (maximum 50 characters).
 Enable; type 1 to enable the sending of text messages or 0 to disable(in this case the fields Receiving Number,
Low Battery Power Text, and Reset Text will be disregarded).