If this spot will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Installing/Replacing the lamp
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
Please follow the lamp manufacturer's notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one 6 V/30 W PAR-36 lamp.
During the operation, the lamp reaches temperatures of up to 130° C.
Procedure:
Step 1: Unscrew the frontcover from the housing.
Step 2: If replacing the lamp, remove the old lamp from the pinspot and loosen the wires.
Step 3: Loosen the screws on the new 6 V/30W PAR-36 lamp with an appropriate screwdriver.
Step 4: Connect the cables of the pinspot via the cable lugs with the lamp.
Step 5: Tighten the screws.
Step 6: Insert the lamp in the housing.
Step 7: Fix the the frontcover on the housing.
Rigging
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the Pinspot has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Disconnect from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
DANGER TO LIFE!