Alarm zone (2)
6
12
1
2
13
14
Single zone EOL
Zone state
Value
0 Ω
Tamper (short)
Normal
Rt
Alarm
Rt+Ra
Tamper (open)
EN: Installation Sheet
Description
DDV1016-N is a dual motion sensor.
It combines the patented PIR mirror optics technology with the
patented Range Controlled Radar technology.
Installation guidelines
See Figure 1.
The detector is intended to be mounted on walls but can also
be mounted on ceilings by using a mounting bracket.
P/N 466-5634-ML • REV D • ISS 19AUG22
Ra
4
JA
Alarm (1)
JT
Rt
Tamper (3)
5
5
7
3
4
6
8
Default
0 Ω
4.7 kΩ
9.4 kΩ
11
JT
SW1 - Generic settings
LED ON
Remote ON
Positive Polarity
Range
2
1
10 m
Use the following guidelines to determine the best location to
install the detector.
Mount the detector so the expected movement of an
intruder is across the detection pattern (see Figure 3).
Mount the detector at a stable surface. For the allowed
mounting height, see "Specifications" on page 6.
Do not mount the detector within 0.5 m of metallic objects
or within 1.5 m of fluorescent lights.
Do not place objects in front of the detector that may
prevent a clear line of sight.
Place detectors at least 6 m apart, and use the short-
range setting to avoid interference, when mounting
detectors face to face.
The dual technology processing of this detector is very
resistant to false alarm hazards. However, avoid potential
causes of instability, such as:
PIR hazards:
Direct sunlight on the detector
Heat sources within the detector field of view
Strong air draughts onto the detector
Animals in the field of view
Obscuring the detector field of view with large objects,
such as furniture
Microwave hazards:
Mounting surface susceptible to vibrations
Metal surfaces reflecting microwave energy
Water movement through plastic pipes
Moving or vibrating objects like fans, heating or air-
conditioning ducts
WARNING!
The equipment is not earthed. Any
external circuit connected to the equipment must be
located within the same building and connected to a
protective earthing conductor.
Wire insulation of cables connected to the equipment must
conform to IEC 60332-1-2 and IEC 60332-1-3 or IEC 60332-
2-2, depending on the wire cross sectional area, or IEC TS
60695-11-21, regardless of cross sectional area. Alternatively,
such wires must comply with UL 2556 VW-1.
The detector power supply source must be power limited at
15 W.