3.
Remove pump oil drain plug.
4.
After oil is drained, replace pump oil drain plug. Tighten securely.
5.
Refill pump using SIMPSON
available, an SAE 15W-40 oil may be used.
6.
Replace pump oil fill plug and tighten securely.
If there is a problem with the pump contact us at www.simpsoncleaning.com
CONNECTIONS
Connections on pressure washer hoses, gun and spray wand should be cleaned
regularly and lubricated with light oil or lithium grease to prevent leakage and
damage to the o-rings.
NOZZLE CLEANING (FIG. 15)
If the nozzle becomes clogged with foreign materials, such as dirt, excessive
pressure may develop. If the nozzle becomes partially clogged or restricted, the
pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit
supplied and the following instructions:
1.
Shut off the pressure washer and turn off the water supply.
2.
Pull trigger on gun handle to relieve any water pressure.
3.
Disconnect the spray wand from the gun.
4.
Remove the high pressure nozzle (K) from the spray
wand. Remove any obstructions with the nozzle cleaning
tool provided and backflush with clean water.
5.
Direct water supply (N) into nozzle to backflush loosened
particles for 30 seconds.
6.
Reassemble the nozzle to the wand.
7.
Reconnect spray wand to gun and turn on water supply.
8.
Start pressure washer and place spray wand into high
pressure setting to test.
CLEAN THE WATER INLET FILTER (FIG. 10)
This screen filter should be checked periodically and cleaned if necessary.
1.
Remove filter by grasping end and removing it from water inlet of pump.
2.
Clean filter by flushing it with water on both sides.
Re-insert filter into water inlet of pump. NOTE: Convex side faces out.
3.
NOTE: Do not operate the pressure washer without filter properly installed.
ENGINE
Consult the Engine Owner's Manual for manufacturer's recommendations for
storage.
TO PREVENT FUEL-RELATED PROBLEMS
1.
Add Ethanol Shield
When adding a gasoline stabilizer, fill the fuel tank with fresh gasoline. If only
partially filled, air in the tank will promote fuel deterioration during storage.
If you keep a container of gasoline for refueling, be sure that it contains only
fresh gasoline.
Premium Pump Crankcase Oil. If this oil is not
®
STORAGE
fuel stabilizer following the manufacturer's instructions.
TM
18- ENG