Descargar Imprimir esta página

Hitachi Koki WH 18DFX Instrucciones De Seguridad Y Manual De Instrucciones página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

English
APPLICATIONS
Driving and removing of machine screws, wood screws,
tapping screws, etc.
REMOVAL AND INSTALLATION METHOD
OF BATTERY
1. Battery removal
Hold the handle tightly and push the battery latch to
remove the battery (See Fig. 5).
CAUTION
Never short-circuit the battery.
2. Battery installation
Insert the battery while observing its polarities (see
Fig. 5).
Insert
Pull out
Battery
CHARGING METHOD
NOTE
Before plugging into the receptacle, make sure the
following points.
○ The power source voltage is stated on the
nameplate.
○ The cord is not damaged.
WARNING
Do not charge at voltage higher than indicated
on the nameplate.
If charged at voltage higher than indicated on the
nameplate, the charger will burn out.
1. Connect the charger's power cord to a receptacle.
When the power cord is connected, the charger's pilot
lamp will blink in red. (At 1-second intervals)
10
ASSEMBLY AND OPERATION
Handle
Latch
Push
Fig. 5
WARNING
Do not use the electrical cord
if damaged. Have it repaired
immediately.
2. Insert the battery into the charger.
Firmly insert the battery into the charger as shown in
Fig. 6 .
Pilot lamp
3. Charging
When the battery is connected to the battery charger,
charging will commence and the pilot lamp will light in
red. (See Table 2)
NOTE
If the pilot lamp fl ikers in red, pull out the plug from
the receptacle and check if the battery is properly
mounted.
When the battery is fully charged, the pilot lamp
will blink in red slowly. (At 1-second intervals) (See
Table 2)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 2, according to the condition of the charger or
the rechargeable battery.
Battery
Fig. 6

Publicidad

loading