DANGER
Drain fuel into approved container outdoors,
away from open flame. Be sure engine is cool.
Do not smoke.
4-FUEL STARVATION:
to "GAS" position. Start and run the generator until it
stops from lack of gasoline. This will dry out all
remaining gasoline in tank, fuel lines and carburetor.
5-Turn fuel selector switch to "OFF" position.
Fully close the LPG cylinder knob if it is open and
disconnect LPG cylinder from the generator.
6-Allow the unit to cool entirely before cleaning
and storage.
7-Change oil with recommended grade oil.
8-Remove spark plug and pour about one teaspoon
of engine oil through the spark plug hole, then pull
the recoil starter several times to distribute the oil for
lubricating the cylinder. Reattach the spark plug.
Pull recoil slowly until resistance is felt. This will
close the valves so moisture cannot enter engine
cylinder. Gently release recoil starter.
9-Cover the unit and store in a clean, dry place
out of direct sunlight. NEVER USE WATER TO
CLEAN GENERATOR.
Note:
We recommend always using a fuel stabilizer.
A FUEL STABLIZER will minimize the formulation
of fuel gum deposits during storage, the fuel
stabilizer can be added to the gasoline in the
fuel tank, or into the gasoline in a storage
container.
If it is not practical to empty the fuel tank and
the unit is to be stored for some time, use a
commercially available FUEL STABILIZER added
to the gasoline to increase the life of the gasoline.
Run the unit for 5-10 minutes to circulate treated
gasoline into the fuel lines abs carburetor before
shutdown. DO NOT STORE GENERATOR WITHOUT
FUEL STABILIZER IN FUEL SYSTEM INCLUDING
TANK, FUEL LINES AND CARBURETOR.
Any damages or hazards caused by using
improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not
covered by manufacturer's warranty.
Do not store gasoline from one season to
another season.
English
Turn fuel selector switch
Battery Charging & Maintenance
The battery powers up the starter motor and the control
module in this generator. This product is equipped with
an automatic battery charging circuit. The battery will
receive charging voltage when the engine is running.
The battery will maintain a proper charge if the unit is
used on a regular basis (about once every two weeks).
If it is used less frequently, the battery should be connected
to a trickle charger (not included) or battery maintainer (not
included) to keep the battery properly charged. If the
battery is not able to start the engine, it can be started
manually only on "GAS" position by pulling the engine
recoil cord. If the battery voltage is extremely low, the
charging circuit may not be able to re-charge the battery.
In this case, the battery must be connected to a standard
automotive style battery charger for re-charging before
it can be used.
WARNING
Generator exhaust contains odorless and
colorless carbon monoxide gas.
To avoid accidental or unintended ignition of
your generator during periods of storage, the
following precautions should be followed:
When storing the generator for short or extended
periods of time make sure that the fuel selector
switch is in the "OFF" position and the battery
leads have been disconnected from the battery.
Repairs/Service Parts
We recommend that you use a FIRMAN authorized
dealer for all maintenance, service, and replacement
parts for engine. To find a FIRMAN authorized dealer
visit www.firmanpowerequipment or call
1-844-347-6261.
Page 32
Customer Service: 1-844-FIRMAN1