ENGLISH
LOCATION REQUIREMENTS
IMPORTANT:
O
conditioner will be installed. Make sure you have everything necessary for correct
installation.
THE LOCATION SHOULD PROVIDE:
• A grounded electrical outlet within 6 ft. (183 cm) of where the power supply cord exits the air
conditioner, for models:
ESA405P-L ESA406P-L ESA408N-L
• A grounded electrical outlet within 4 ft. (122 cm) of where the power supply cord exits the air
conditioner, for models:
ESA410N-L ESA412N-L
NOTE: o
D not use an extension cord, plug adapter, surge protector or multi-outlet adapter.
• Free movement of air in the room to be cooled.
• A large enough opening for the air conditioner. (See Fig.1)
• The air conditioner must not be installed in a through-the-wall sleeve
or in a wall. It can only be installed in a double-hung window.
NOTE: The outside cabinet louvers must not be obstructed by bushes,
trees, etc. Air must be able to pass freely through the cabinet
louvers. (See Fig.2)
CABINET LOUVERS
WINDOW INSTALLATION
Window opening measurements: (See Fig.1)
A. Width Min/Max
B. Height Min
PAGE 6
s b
r e
e v
all governing codes and ordinances. Check the location where the air
Fig. 2
ESA405P-L
ESA406P-L
21-7/8" - 36"
24-1/2" - 36"
13-3/8"
13-3/8"
WIDTH
INSTALLATION REQUIREMENTS
Fig. 1
ESA408N-L
ESA412N-L
ESA410N-L
25" - 36-21/32"
26-1/8" - 37-25/32"
14-9/16"
14-9/16"
WIDTH
B-HEIGHT
A-WIDTH
AIR DISCHARGE
HEIGHT
WIDTH