4.2 - Add a configured spot in the USER file :
For a spot to be configured, it is possible to configure:
The pre-tightening stage
The pre-heating stage
The different pulses (4 pulses maximum)
And the hot and cold forging stage.
To change the settings, click on the buttons
When the operator changes a parameter, the spot chronogram is updated.
To validate the spot configuration, click on the button
To cancel the spot configuration, click on the button
4.3 - Modify a spot configured in the USER file:
To change the settings of a spot, select a spot from the list and then change the welding settings.
To validate the changes, click on the button
To cancel the changes, click on the button
4.4 - Delete a configured point in the USER file:
Select a spot parameter from the list and click on the button
Raison sociale :
JBDC
Adresse :
ZI, 134 Bd des Loges
Code postal :
53941
Ville :
Saint-Berthevin
Intervenant :
OPERATEUR
Ordre de réparation :
977AC92
Date du journal :
05/04/2018
Intervention :
AILE ARRIERE
Commentaires :
Commentaires
GYSPOT BP.LG (1712009013)
Id
Date
Mode
Outil
1
05/04/18 10:22
Auto
Pince en C n°1
2
05/04/18 10:22
Auto
Pince en C n°1
3
05/04/18 10:22
Auto
Pince en C n°1
4
05/04/18 10:22
Auto
Pince en C n°1
5
05/04/18 10:22
Auto
Pince en C n°1
6
05/04/18 10:23
Normal
Pince en C n°1
7
05/04/18 10:23
Normal
Pince en C n°1
8
05/04/18 10:23
Normal
Pince en C n°1
9
05/04/18 10:23
Normal
Pince en C n°1
10
05/04/18 10:23
Normal
Pince en C n°1
11
05/04/18 10:23
Manuel
Pince en C n°1
SPOT TRAFO 14500
Then double-click in the second column to select a manufacturer file previously downloaded from our
website.
The list of spots set by the manufacturer is displayed in the second list. Select a configured point to
view the chronogram and configured parameters.
To add a spot to the USER file, select the USER file from the file list and click on the button
right of the list of configured spots. Enter the name of the spot and press the TAB key or click outside
the list of configured spots to configure the welding parameters.
.
.
.
.
.
to the right of the list.
Téléphone :
0243510101
Télécopie :
0243510102
Email :
contact@companyname.com
Site Web :
www.companyname.com
Marque :
PEUGEOT
Modèle :
308SW
N° châssis :
12365849
Immatriculation :
1450UT53
Mise en circulation :
01/01/2017
Consignes
Mesures
Temps
Serrage
Serrage
Intensité (kA)
Intensité (kA)
(ms)
(daN)
(daN)
630
9,4
325
9,4
630
9,4
325
9,3
490
8,2
240
8,2
510
8,3
250
8,2
510
8,3
250
8,3
350
7,3
225
7,3
350
7,3
225
7,2
400
8,1
265
8,0
400
8,1
265
8,1
400
8,1
265
8,1
400
8,1
510
8,1
Etat
Epaisseur
(mm)
325
3,5
Point Ok
325
3,5
Point Ok
240
2,0
Point Ok
245
2,1
Point Ok
245
2,1
Point Ok
-
225
Point Ok
-
225
Point Ok
-
265
Point Ok
-
260
Point Ok
-
270
Point Ok
-
440
Pression faible
EN
to the
51