Trimmer Functions; Advanced Programming - Beninca DA.BA Libro De Instrucciones

Centralita a microprocesador
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
LED functions
+36V (green)
Power on signal for +36V power circuit; if it does not light up check fuses F6, F5.
+24V (green)
Power on signal for +24V circuit; if it does not light up check fuse F5.
+5V (green)
Power on signal for +5V logic circuit. If it does not light up check fuse F5.
A (green)
Signals motor is in open cycle.
C (red)
Signals that motor is in close cycle.
PROG (yellow)
Blinking during normal operation of control unit.

Trimmer functions

LIM-A
It regulates the intervention threshold of the torque regulator of the motor in the opening phase (max
in clockwise direction).
LIM-C
It regulates the intervention threshold of the torque regulator of the motor in the closing phase (max in
clockwise direction).
TCA
It regulates the automatic closing time from 0 to 240 seconds (max in clockwise direction).
Dip-switch functions S2
DSW1
Function "Forewarning": the flashing light is activated 3 seconds before the beginning of each operation.
Off= Disabled
On= Enabled
DSW2
"Automatic close" function: for safety reasons the "Automatic Close" function is always disabled after a signal
is given to the "STOP" inputs. A signal to the "ASC" input will not interrupt the "Automatic Close" function if
the motor is off.
Off= Disabled
On= Enabled
DSW3
"Condominium" Function: the "P.P." input will not stop the motor during the open cycle. When the open
cycle is completed, the "P.P." input is enabled to close the barrier.
Off= Disabled
On= Enabled
DSW4
Electric lock enabled
Off= Disabled
On= Enabled
DSW5
Operating mode for the "P.P." input.
Off= Open/Stop/Close/Stop sequence
On= Open/Close sequence
DSW6
ASC edge trips in close cycle
Off= When edge trips the barrier changes direction.
On= When edge trips the barrier changes direction for 1 sec. and stops.
DSW7
Photocell trips (Dip2 set to ON)
Off= When photocell trips the automatic close delay remains unchanged.
On= When photocell trips the automatic close delay is shortened to 1 sec.
DSW8
Beacon operating mode
Off= During open cycle the beacon goes out.
On= During open cycle the beacon keeps flashing.
The functions linked with dip-switches are active after a full operation from the change in dip-switch settings.
IMPORTANT NOTE:
To program the advanced functions, a special Dip-Switch combination should be provided for selector switch S2. The
function should then be stored in memory by pressing button S3 until the yellow PROG LED switches off.
At completion of the advanced programming procedure, the Dip-Switches S2 should be moved to the original position.
To facilitate this operation, take note of the basic settings in the following table.

ADVANCED PROGRAMMING

� � � � � � � �
��
13

Publicidad

Tabla de contenido
loading

Tabla de contenido