Cleaning metal grease filters
These can be washed in the dishwasher, and need to
be cleaned whenever the S1 LED comes on or at least
once every 2 months of use, or more frequently if use
is particularly intensive.
Resetting the Grease Filter Alarm
• Turn the Lights and the Hood off.
• Press
and hold for at least 3 seconds, until
LED flashes three times in confirmation.
T1
T2
T3
Cleaning the Filters
• Open the Panel.
• Remove the Filters one at a time, pushing them
towards the back of the unit and at the same time
pulling downward.
• Wash the Filters without bending them, and leave them
to dry completely before replacing. (If the surface of
the filter changes color as time goes by, this will have
absolutely no effect on the efficiency of the filter itself.)
• Replace the grease filters, taking care to ensure that
the handle faces forward.
• Completely dry the filters before reinstalling.
Otherwise, left over grease may heat and drip.
• Close the Panel.
Replacing Activated Charcoal Filter
They cannot be washed or regenerated, and must be
changed when LED S1 starts to flash, or at least once
every 4 months. The Alarm signal, if it has been activated,
only appears when the Hood Blower is turned on.
Resetting the alarm signal
• Turn the Lights and the Hood Blower off.
• Press
and hold for at least 3 seconds, until
LED flashes three times in confirmation.
T1
T2
T3
Cleaning the Filters
• Open the Panel.
• Remove the Metal Grease Filter.
• Remove the saturated Activated Charcoal Filters, as
indicated (A).
• Fit the new Filters, as indicated (B).
• Replace the Metal grease filters.
• Close the Panel.
S1
T4
S1
T4
1
2
3
A
B
31