Opening The Casing - Auerswald COMpact 5200 Manual De Instrucciones

Centralita para telefonía analógica, rdsi y por internet
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Requirements:
• Screw driver (Phillips)
• Connecting cable with at least 2.5 mm
tion
• Grommet (ring-shaped cable shoe: insulated or non-insulated)
with an inner ring diameter of 4 mm min. and 6 mm max.
• Proper earth connection close to the installation site (equipo-
tential bonding rail of the house installation or protective earth
conductor)
1.
Connect the connecting cable to the potential compensation
bar of the house installation or the protective earth conductor.
2.
Guide the connecting cable to the rear side of the casing.
3.
Join the grommet to the connecting cable and attach it to the earthing terminal

Opening the Casing

Warning: Improper handling of the device can cause life-threatening electric shocks
and can damage or destroy the PBX.
• Only a qualified electrician may open the casing and perform installation work within an
open casing.
Warning: Touching voltage-carrying conductors or telephone connections can cause
life-threatening electric shocks. The PBX contains hazardous voltages, even outside
of the power supply unit (for instance ringer voltages). Work on active, contact-hazard-
ous parts is only permitted after creating a voltage-free state. Working close to active parts
is only permitted if these parts are voltage-free or are protected against direct contact.
• Disconnect the power plug of the PBX and its accessories before instructing a qualified
electrician to open the casing. Also disconnect the device from additional power sources
(e. g. UPS, if installed).
• Wait at least 3 minutes for the discharge of any capacitor in the device after disconnecting
it from the main power supply.
Warning: Power surges, which may occur during electrical storms, can cause life-
threatening electric shocks, or damage or destroy the PBX.
• Do not touch the PBX or any devices connected to it during an electrical storm.
Requirements:
• Screw driver (Phillips)
1.
Loosen the four screws which hold the front panel.
2.
Lift the front panel off the casing.
COMpact 5200/5200R/5500R - Instructions V01 03/2017
Commissioning (COMpact 5200R/5500R)
²
conductor cross-sec-
47

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Compact 5200rCompact 5500r

Tabla de contenido