Descargar Imprimir esta página

GE JGP985 Manual Del Propietario E Instrucciones De Instalación página 32

Estufa de cubierta a gas con tiro descendente

Publicidad

Idiomas disponibles

Idiomas disponibles

CONVERT SURFACE BURNERS
2
Turn counterclockwise to remove
Remove all grates and burner modules.
A
With an adjustable wrench or an open end wrench,
B
remove the brass orifices.
C
Find the inscribed LP orifices in the holder in the
front of the electric cover beneath the cooktop.
Install the inscribed LP orifices in place of the
D
natural gas orifices.
Replace the burner modules and grates.
E
Keep all the spuds with your cooktop so you have
F
them if you move or get a different gas hook-up.
LP (Propane) Gas 10" W.C.P.
Burner Output Rating in BTU/HR
Location
BTUs
Left Rear (LR)
9,100
Left Front (LF)
9,100
Right Rear (RR)
9,100
Right Front (RF)
9,100
LP Conversion Instructions
Turn clockwise to tighten
Orifice
Orifice Size
Engraving
.0354
LP
.0354
LP
.0354
LP
.0354
LP
ADJUST GRILL BURNER
3
AIR SHUTTER
Air shutter
The air shutters for the grill burner may need to be
adjusted to get better flame appearance and ignition. The
air shutters for the grill burner are located on the bottom
of the grill burner. To access the air shutters, remove the
grill grate, and then the grill burner. Slide air shutter
backward or forward to increase or decrease the size of
the air opening. Air shutters fit snugly on the grill burner,
so a screwdriver blade may be required to make this
adjustment (see illustration). The snug fit of the air shutter
assures it will remain positioned correctly.
CHECK IGNITION
4
A
Connect electrical supply cord.
B
Turn on the gas; check for leaks using a liquid leak
detector at all joints in the system.
WARNING:
TO CHECK FOR GAS LEAKS.
Push in one control knob and
turn to the LITE position. The
igniter will spark and the burner
will light. The first test may
require some time while air is
flushed out of the gas line. After
ignition, turn the control knob
to the HI position and wait until the flame settles.
C
Check to determine if your burner flames are
normal. If burner flames look like A, turn off the
burner and make sure all parts are assembled
correctly. Reassemble and check.
Normal burner flames should look like B or C,
depending on the type of gas you use. With LP gas,
some yellow tipping on outer cones is normal.
A–Yellow flames
Not normal;
check alignments
D
Turn the knob to OFF.
E
Repeat the procedure for each burner.
32
Insert screwdriver blade in
slot and twist with slight
pressure to allow air shutter
to slide easily
DO NOT USE A FLAME
B–Yellow tips
C–Soft blue flames
Normal for
Normal for
LP gas
natural gas

Publicidad