Chapter 2 Installation
2.2. Installation guide
2.2.1. Measuring liquid
(1)Flat-top tank
Flat-top tanks generally have a very short nozzle. The reference surface of the
nozzle is the bottom surface of the flange. When the length of the nozzle is
≤60mm, the inner diameter of the nozzle is ≥100mm, and the inner wall of the
nozzle is flat without burrs or protrusions, the probe is installed after installation.
The emission surface can be measured 3cm below the bottom surface of the
flange.
Flange installation - installed in a short nozzle
The most ideal installation is to directly install the instrument on a flat-top container.
Without using a nozzle, the circular opening on the container can be sufficient to
fix the flange or universal joint for installation. The emitting surface of the probe is
below the reference plane.
- 5 -