Chapter 4 Menu and operation
Communication parameters
1.
Display unit
2.
Com Setting
3.
User parameter
4.
Factory Param.
【SET】
Device ID: 001
Baud rate: 2400
Parity:
None
Endian: 3412
User parameters
1.
Display unit
2.
Com Setting
3.
User parameter
4.
Factory Param.
【SET】
Measure mode:
Level
- 24 -
RS485 communication parameter setting
Table number: 1-254 can be set.
Baud rate: 1200, 2400, 4800, 9600, 19200
and 38400BPS are optional.
Verification: None, even and odd verification
are optional.
Byte order: the floating number is specified
to represent the time byte order.
Communication connection refers to 485
communication instructions.
(Note: 485 is optional)
Measurement mode: level measurement
and distance measurement are optional.
The output of the failure state is the current
output when the ultrasonic level meter is in
abnormal state, and can be selected from
hold, set, maximum and minimum values.
The maximum value corresponds to 22mA