Installation- Ducting Version
After having choosen the vent option, proceed as follows:
1
Remove the grease filters.
2
Remove the junction box cover. Remove either the top or
the back wiring knockout according the preference and
install an approved wiring clamp.
J-Box cover
Wiring clamp
3
Remove the screws (2) located in the 7" round transition
and keep them in a safe place.
7" round transition
4
Remove the duct knockouts using a flat blade screwdriver
and a small hammer. Use the screwdriver by knocking
out the pannel in similar fashion to a scalpel. Take care of
sharp edges.
I
ATTENTION
If it is intended to use the hood in the recirculating version do
not remove any duct knockouts and order the necessary
charcoal filter from your supplier.
R1 = Remove rectangular duct knockout only.
R2 = Remove semicircular and rectangular duct knockouts.
2 screws - 3.5 x 6.5 mm
R1
Rectangular
vertical discharge
For rectangular ducted discharge installations only
5
Attach exhaust adaptor/damper over knockout opening
with three exhaust adaptor screws. Use the screws
previously removed in step 3.
Make sure damper pivot is nearest to top/back edge of
hood. Remove tape from damper flap.
NOTE: The exhaust adaptor/damper can be installed up to 1 inch
on either side of the hood center to accommodate off-center
ductwork. In extreme offcenter installations, one end of the duct
connector may need to be trimmed to clear the electrical cable
clamp.
Pivot
For round ducted discharge installations only
6
Install 7" (17.8 cm) transition, use the screws previously
removed in step 3.
NOTE: The round transition can be installed up to 1 inch on
either side of the hood center to accommodate off-center
ductwork. In extreme offcenter installations, one end of the
duct connector may need to be trimmed to clear the electrical
cable clamp.
7" round transition
R2
Round vertical
discharge
R1
Rectangular
horizontal discharge
Top/back edge
Exhaust transition/ damper
7