Descargar Imprimir esta página

Tennant NOBLES SPEEDSHINE 1600 Manual Del Operador Y Repuestos página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
TROUBLE SHOOTING
PROBLEM
Motor does not operate.
Machine circuit breaker trips
continuously.
Pad spins slowly or not at all.
SPECIFICATIONS
SPEEDSHINE 1200
MODEL
WIDTH
20.75 in / 530 mm
HEIGHT
49 in / 1,240 mm
LENGTH
29.75 in / 760mm
WEIGHT
68 lb / 31 kg
DRIVE MOTOR
120 V, 1.5 hp, 15 A, 60 H
PAD/BRUSH SPEED
1,200 rpm
POWER CORD
75 ft / 23 m Gauge 3 X 1.5 mm
LENGTH
PAD DIAMETER
20 in / 510 mm
DECIBEL RATING AT
70 dBA
OPERATOR'S EAR,
INDOORS ON TILE
FLOOR
10
CAUSE
Machine circuit breaker tripped.
(Spray buffing with the 1600 and 2000
rpm models is not recommended).
Building circuit breaker tripped.
Faulty power cord.
Faulty wiring.
Faulty twist grip switch.
Faulty Rectifier.
Faulty Motor.
Soiled Pad.
Improper pad for application.
Defective circuit breaker.
Worn carbon brushes in motor.
Loose drive belt.
Broken drive belt.
SPEEDSHINE 1600
20.75 in / 530 mm
49 in / 1,240 mm
29.75 in / 760mm
68 lb / 31 kg
120 V, 1.5 hp, 15 A, 60 H
Z
1,600 rpm
75 ft / 23 m Gauge 3 X 1.5 mm
20 in / 510 mm
70 dBA
Home
Find... Go To..
SOLUTION
Determine cause and reset breaker on
machine. Wait 15 seconds before
restarting machine.
Reset breaker and change to different
circuit.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Contact Service Center.
Replace Pad.
Change to proper pad.
Contact Service Center.
Contact Service Center.
Tighten drive belt.
Replace drive belt.
SPEEDSHINE 2000
20.75 in / 530 mm
49 in / 1,240 mm
29.75 in / 760mm
68 lb / 31 kg
120 V, 1.5 hp, 17A , 60 H
Z
2,000 rpm
75 ft / 23 m Gauge 3 X 1.5 mm
20 in / 510 mm
70 dBA
Speedshine 1200/1600/2000 (06- -06)
Z

Publicidad

loading