5. After re-assigning a keypad, perform a supervisory reset by entering[
and wait for 60 seconds.
6. Press [#] twice to exit after 60 seconds.
3.4 Manually Enroll Wireless Devices/Keypads
To manually enroll a 2-way wireless device:
1. Enter [
][8][Installer Code][804].
,
2. Enter the 3-digit zone/slot corresponding to the device type:
Wireless sensors, pendants, repeaters [804][001]-[064] (excluding [029]-[032])
Wireless Key
Wireless Keypad
NOTE: Hardwired and wireless devices cannot be assigned to the same zone. PC5108 zone
expander modules occupy zones in 2 groups of 4 (e.g., zones 9-12 and zones 13-16). None of
the zones assigned to a PC5108 module may be used for wireless devices. For more
information on zone assignment, consult the system installation manual.
A wireless key can only be assigned to one partition (partition 1 by default). To assign keys to a
different partition, see "[804][183] Wireless Key (1-16) Partition Assignments" on page 20.
3. Enter the device serial number. On PK keypads, this is a 6-digit entry. When entering an 8-digit
ESN, do not program the first two digits. On WT keypads, this is an 8-digit entry. When
programming a 6-digit ESN, enter 00 for the first two digits. To toggle between decimal and
hexadecimal values, press [
system installation manual. The device is now enrolled on the system.
4. Record the serial number and the assigned zone number in the programming worksheets at the
back of this manual.
5. Continue with steps 2 - 4 until all wireless devices are enrolled.
6. Press [#] to exit.
NOTE: Zone and partition programming must be completed for the wireless devices to
operate correctly (see Section 4.1, page 8).
NOTE: (For non-UL listed installations) For Repeaters and Wireless Keypads, non-alarm
zone type 26 is recommended. With this zone type, loss of AC or a Low battery condition are
not reported to the central station. The alarm panel does not show a trouble for the zone but
will indicate it as open. Select the Force Arm attribute for this zone. Program a zone label to
identify the WS4920 or WT5500. E.g., "Rptr 1 Pwr Trbl."
NOTE: (For UL listed installations) If AC loss and low battery must be reported to the
central station, use a 24-hour zone type. Ensure the Audible attribute is set to Silent.
To delete a wireless device:
1. At a system keypad, enter [
2. Enter the 3-digit number corresponding to the zone you want to remove the device from.
3. Program the ESN as [00000000]. The device is deleted.
4. Press [#] to exit.
Once all wireless devices are enrolled, program the system to work with the devices. See 4.1
"Program Zones and Partitions" on page 8 for more information.
[804][101]-[116] for wireless key numbers 01- 16
[804][029]-[032]
]. For instructions on programming hexadecimal numbers, see the
,
][8][Installer code][804].
,
7
][8][Installer Code][902]
,