Descargar Imprimir esta página

EINHELL GC- DW 1000 N Manual De Instrucciones Original página 16

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 76
10. Troubleshooting guide
Faults
The equipment
does not start
The equipment
does not pump
Insuffi cient pumping
rate
The equipment swit-
ches off after briefl y
running
Anl_GC_DW_1000_N_SPK7.indb 16
Anl_GC_DW_1000_N_SPK7.indb 16
GB
Cause
- Power supply not connected
- Intake sieve clogged
- Discharge hose kinked
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Motor circuit-breaker switches the
equipment off due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
- 16 -
Remedy
- Check power supply
- Clean intake sieve with water jet
- Unkink the hose
- Clean intake sieve
- Clean equipment and replace wear
parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
23.08.2016 10:08:42
23.08.2016 10:08:42

Publicidad

loading

Este manual también es adecuado para:

41.709.55