MAXIMUM TEMPERATURE ADJUSTMENT

CAUTION: The maximum temperature setting must be adjusted in the
following situations:
After initial installation of the valve.
After servicing or replacing the valve cartridge.
After any adjustments, replacements, or repairs to equipment
supplying hot water to the valve.
Seasonally to compensate for temperature variation in the water
supply.
Temperature
Stop
O-Ring
1. Remove the o-ring.
2. Remove the temperature stop.
3. Monitor water temperature with thermometer and rotate valve stem
counterclockwise until desired water temperature is reached. Do not
set the water temperature above 120° F (49°C).
4. Reinstall the temperature stop so that is touching the bonnet tab,
preventing further counterclockwise rotation of the valve stem.
5. Reinstall the o-ring to secure the temperature stop.
Bonnet Tab