MAXIMUM TEMPERATURE ADJUSTMENT
CAUTION: The maximum temperature setting must be adjusted in the
following situations:
•
After initial installation of the valve.
•
After servicing or replacing the valve cartridge.
•
After any adjustments, replacements, or repairs to equipment
supplying hot water to the valve.
•
Seasonally to compensate for temperature variation in the water
supply.
Temperature
Stop
O-Ring
1. Remove the o-ring.
2. Remove the temperature stop.
3. Monitor water temperature with thermometer and rotate valve stem
counterclockwise until desired water temperature is reached. Do not
set the water temperature above 120° F (49°C).
4. Reinstall the temperature stop so that is touching the bonnet tab,
preventing further counterclockwise rotation of the valve stem.
5. Reinstall the o-ring to secure the temperature stop.
Bonnet Tab
5