Using The Blow Nozzle; Changing The Exhaust Direction - Hitachi Koki NT 65MA4 Instrucciones Y Manual De Seguridad

Clavadora de acabado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Adjuster
If nails are driven too shallow, turn the adjuster
to the deep side.
3 Stop turning the adjuster when a suitable
position is reached for a nailing test.
4 Connect the air hose.
ALWAYS WEAR SAFETY GLASSES.
Perform a nailing test.
5 DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
2
Turn Adjuster
Too Deep
2
Too Shallow
Turn Adjuster

Using the blow nozzle

● Be sure to release your fi nger from
the trigger before using the blow
nozzle.
● Do not point the air outlet at a
person.
● Do not use the blow nozzle with the
push lever left fi t.
16
15 Disconnect air
hose
Flush
Flush
WARNING
This Nailer has a blow nozzle that blows out
wood shavings which occur during work.
Press the knob with your thumb to use the blow
nozzle, as shown in the fi gure.
Air outlet
NOTE
● When the blow nozzle is used for a long time,
the nailing force may degrade temporarily.
In this case, allows the air supply pressure
to stabilize before starting work.
● Oil in the body or drained water from the
compressor can sometimes spout out
of the air outlet. It is recommended that
you once conduct a test before use and
see if such phenomenon happens at an
environment where spouted oil will cause
any inconvenience.

Changing the exhaust direction

● When
changing
direction,
your fi nger from the trigger and
disconnect the air hose from the
nailer.
The direction of the exhaust vent can be
changed by turning the top cover.
Exhaust
Vent
Knob
WARNING
the
exhaust
be
sure
to
remove
Top Cover

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Nt 65ma4s

Tabla de contenido