TECHNICAL SPECIFICATION
MODEL
Basic features
Number of verification
scale interval
Weight range
Power supply
Battery estimated use time
Working temperature
Working humidity
Accuracy class
Weighing capacity (Max.)
Verification scale interval
Weighing capacity (Min.)
Tare (Max.)
Platter size
OPERATION
Make sure the scale is placed at the steady platform and then power on. You
can set the unit, the time of auto power saving, time of switching backlight,
decimal point and input method, please take explanation for your reference:
8
ZFOC
Backlight
0-15-30 kg
3pcs AA batteries
5000 hours / 20 months
0 ºC – 40 ºC
5 % - 85 %
6/15 kg
2/5 g
40 g
-5.998 kg
Stainless steel platter - 330*230
ZFOC - RS
Backlight and RS232
n=3000
RS232USB and 3 AA
batteries
15/30 kg
5/10 g
100 g
-9.995 kg