Using the torque and angle wrench
During the bolting process in "Track" function mode,
the following displays and signals are provided
depending on the settings which have been
undertaken:
 The current torque or angle value is displayed.
 If an alert limit has been set in the
CONFIGURATION menu, the current value is
shown in yellow as of reaching the alert limit. The
signal lamps light up yellow.
 If a tolerance range has been set and this has
been reached, the current value is shown in
green. The signal lamps light up green. A short
audible signal is heard.
 If the previously set upper target torque or target
angle tolerance range is exceeded, the current
value is shown in red. The signal lamps light up
red. A long audible signal is heard.
In this function mode, the values are not saved
automatically after a bolting process. You may
still save the values. To do this, press OK twice
after tightening.
Working in "Peak" function mode
 Monitor the torque or angle value on the display
during tightening.
 Tighten evenly and, in the final phase, without
interruption until the set or desired target torque or
target angle value can be seen.
During the bolting process in "Peak" function mode,
the following displays and signals are provided
depending on the settings which have been
undertaken:
 The current torque or angle value is displayed.
 If an alert limit has been set in the
CONFIGURATION menu, the current value is
shown in yellow as of reaching the alert limit. The
signal lamps light up yellow.
 If a tolerance range has been set and this has
been reached, the current value is shown in
green. The signal lamps light up green. A short
audible signal is heard.
 If the previously set upper target torque or target
angle tolerance range is exceeded, the current
value is shown in red. The signal lamps light up
red. A long audible signal is heard.
 The peak value which has been reached is shown
on the display. OK must be pressed to
acknowledge the display.
In this function mode, the values are not saved
automatically after a bolting process. You may
still save the values. To do this, press OK twice
after tightening.
Controlled left-hand tightening
Controlled left-hand tightening can be carried out
without further settings in the "Track" and "Peak"
function modes.
Controlled left-hand tightening can be carried out in
"Click" function mode. If a plug-in ratchet is used for
this, install it rotated by 180°.
45