Description
Symbol
Explanation
Battery status indicator
Clockwise
Counter-clockwise
Angle measurement running
Taring process running
Taring process ended
Move upwards, increase values
Move downwards, reduce values
Administrator password required
No standard extension length set
An error has occurred
14
Direct input, measuring and function
modes
MANOSKOP
direct input
®
Concrete values for a bolting operation are defined
in direct input.
The torque and angle wrench offers both torque and
angle mode.
The different measuring modes are used to define
the tightening process with which the bolting
operation is performed. After switching on, the
torque and angle wrench is always in one of the
four following measuring modes.
 Torque
 Angle
 Torque-angle
 Angle-torque
Torque
In this measuring mode, a threaded connection is
only implemented according to the target torque.
The torque and angle wrench evaluates the
measured torque and responds with corresponding
signals:
 Signal lamps
 Audible signal
 Colour representation of the display value
 Electromechanical triggering
For this to occur, you must have input the specified
values into the torque and angle wrench.