Descargar Imprimir esta página

Stahlwille MANOSKOP 714 Manual De Instrucciones página 75

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 183
Description
Angle
In this measuring mode, bolting is only implemented
according to the angle. Angle measurement begins
after exceeding the preload. The torque and angle
wrench evaluates the angle and responds with
corresponding signals:
 Signal lamps
 Audible signal
 Colour representation of the display value
 Electromechanical triggering
For this to occur, you must have input the specified
values into the torque and angle wrench.
Torque-angle
In this measuring mode, the torque and angle are
evaluated. To obtain a positive bolting operation
evaluation, both values must lie within the defined
tolerance range. The stop signal is triggered on
reaching the target torque. Angle measurement
begins after exceeding the preload.
The torque and angle wrench responds with
corresponding signals:
 Signal lamps
 Audible signal
 Colour representation of the display value
 Electromechanical triggering
For this to occur, you must have input the specified
values into the torque and angle wrench.
Angle-torque
In this measuring mode, the torque and angle are
evaluated. To obtain a positive bolting operation
evaluation, both values must lie within the defined
tolerance range. The stop signal is triggered on
reaching the target angle. Angle measurement
begins after exceeding the preload.
The torque and angle wrench responds with
corresponding signals:
 Signal lamps
 Audible signal
 Colour representation of the display value
 Electromechanical triggering
For this to occur, you must have input the specified
values into the torque and angle wrench.
Function modes
The desired function mode must be assigned in
each of the four measuring modes.
The following function modes are available:
 Click (C)
 Peak (P)
 Track (T)
This is queried each time whilst a bolting operation
is being configured.
Click
The torque and angle wrench triggers
electromechanically on reaching the set target
torque or target angle. When saving is activated,
saving is carried out automatically following relief.
15

Publicidad

loading