Unit is marked with the following symbols:
This symbol indicates that electrical and electronic products must not be
mixed with unsorted household waste. Do not attempt to dismantle the
system on your own. All works involved in dismantling the system, handling
the refrigerant, oil and other components must be carried out by authorized
installation personnel, and the works must be carried out in accordance with
the applicable law. The unit must be disposed of and treated at special
treatment facilities for reuse, and recycling. By making sure that this product
is properly handled and disposed of, you help to minimize the negative
impact on the environment and human health. For more information, please
contact the installation personnel or local organization.
5 Operations
5.1 Operating Range
Cooling mode
Outdoor temperature
-5~48
Indoor temperature
17~32
Indoor humidity
≤80%
(a) Condensation will form on the unit surface and water dripping
out of the unit when the indoor humidity is beyond 80%
Note
The temperature should below 55°C during transporing
The safety device will be triggered if the temperature or humidity
exceeds these conditions, and the air conditioner may not run.
5.2 Operating System
5.2.1 About the system operations
▪ The operating program varies with different combinations of
outdoor unit and controller.
▪ To protect this unit, please turn on the main power supply 12 hours
before you start to operate this unit.
▪ If there is a power outage while the unit is running, the unit will
automatically restart its operation when the power supply resumes.
5.2.2 About the cooling, heating, fan only and auto operations
▪ The indoor units in the air conditioner can be controlled separately,
but the indoor units in the same system cannot operate in the
heating and cooling modes at the same time.
▪ When the cooling and heating modes conflict, the mode is
determined based on the setting of the "S5" mode switch of the
outdoor unit.
Modalità raffreddamento
Temperatura esterna
-5~48
Temperatura interna
17~32
Umidade interna
≤80%
(a) La condensa si formerà sulla superficie dell'unità e l'acqua
gocciolerà fuori dall'unità quando l'umidità interna è superiore
all'80%
Heating mode
(DB)
-25~24
(DB)
°C
°C
(DB)
15~27
(DB)
°C
°C
(a)
Modalità riscaldamento
(DB)
-25~24
(DB)
°C
°C
(DB)
15~27
(DB)
°C
°C
(a)
Automatic
Automatic selection of heating or cooling priority is
priority mode
based on the ambient temperature.
Heating priority
Indoor units in the cooling or fan mode will stop running,
mode
while indoor units in the heating mode will run as usual.
When you select the cooling mode as the priority mode, the
Cooling priority
heating operations in the indoor unit stops running, while the
mode
cooling mode will operate as usual;
If the indoor unit 63 has been set and is turned on, the
No.63
operating mode of unit 63 will be regarded as the priority
(VIP indoor
operating mode of the system. If the indoor unit 63 has not
unit)
been set or not turned on, the mode adopted by most indoor
+ voting
units at the same time will be the priority operating mode of
priority mode
the system.
In response to
Indoor units with the heating mode will operate normally,
heating mode
while indoor units in the cooling or fan mode will display the
only
"E0 conflict".
In response to
Indoor units in the cooling and fan modes will operate
cooling mode
normally, while indoor units in the heating mode will display
only
the "E0 conflict".
5.2.3 About the heating operation
Compared to the cooling operation, the heating operation takes a
longer time.
Need to perform the following operations to prevent the heating capacity
from dropping or prevent cold air from coming out of the system.
Defrost Operation
In the heating operation, as the outdoor temperature decreases, frost
may be formed on the heat exchanger in the outdoor unit, making it more
difficult for the heat exchanger to heat up the air. The heating capacity
decreases, and a defrosting operation needs to be performed on the
system in order for the system to provide sufficient heat to the indoor unit.
At this point, the indoor unit will show the defrost operation on the
display screen.
The indoor fan motor will automatically stop running so as to prevent
cold air from coming out of the indoor unit when the heating operation
starts. This process will take some time. This is not a malfunction.
i
Information
▪ When there is a drop in the external temperature, the heating
capacity decreases. If this happens, please use another heating
equipment and unit at the same time. (Make sure the room is
well ventilated if you are using an equipment that produces fire.)
Do not place any equipment that may produce a fire where the
air outlets of the unit are or below the unit itself.
▪ Once the unit starts, it takes some time for the room temperature to
rise, as the unit uses a hot air circulation system to heat the room.
▪ If the hot air rises to the ceiling, causing the ground area to
become cold, it is recommended that you use a circulating device
(to circulate the indoor air). Please contact the agent for details.
5.2.4 Operating system
1. Press the "switch" button on the controller.
Result: The running light turns on and the system starts to run.
2. Repeatedly press the mode selector on the controller to select the
required operation mode.
Stop
1. Press the "switch" button on the controller again.
Result: The running light is now off, and the system stopped
running.
2
HTW V10
.