Operations
3
11
10
23
9
86404580 VERSAMATICPLUS 14 & 18
Brush Controller
The electronic brush controller monitors the
operation of the brush.
Green light: Brush set correctly and running.
Green and red light: Brush too high. Adjust the
brush setting by turning the pile adjustment knob (19)
to lower setting.
If the green and red light are still on at position
number one the brush strip is worn out and must be
replace.
Red light blinking: The brush is blocked and is not
turning. Switch machine off, unplug from the socket
and clear the blockage.
Filter Level Indicator
If warning light (3) comes on check:
Is the dust bag full?
Is there a blockage in the hose (12) or power
head (9)?
Swivel Neck Latch
To release the machine from the upright position
depress the foot pedal (11).