The ULTRA 9000 pump has been designed to allow the
almost total disassembly of its components, to facilitate
correct use, simple maintenance and ensure long life.
Below is the list of individual parts and related spare parts
(
) - exploded view:
1.
Motor body completely submersible and insulated with
two-component resin
2.
Rotor assembly with À ange, impeller and bearing;
3.
Rear Ceramic Bearing (Extraction Hook Accessory)
4.
Rubber seals
5.
Volute including grid adjustable in height using the 4
feet;
6.
Interchangeable outlets: vertical and 90°;
7.
Security lock for outputs;
8.
Float for automatic ON-OFF function;
9.
Float's cover
10. Graduated hose connector
For the physical installation of the pump it is necessary to proceed as follows:
Unwind the power cord of the pump in an area where it cannot be damaged in any way.
If required, thread a rope (for the recovery of the pump) though the hole in the cover (
The pump is pre-assembled with a vertical outlet: if you wish to use the 90° one, follow the instructions in
(
). The outlets have a 1" ½ GAS male thread. It is possible to connect the stepped hose connector
supplied or any other type of ¿ tting with that thread;
Place the pump in a À at area that is easily accessible for maintenance operations;
If the pump is not stable, adjust one or more feet separately (
To suck the water up to the minimum level of 5 mm allowed by the pump, leave the grate closed (
If this requirement is not met, it is advisable to adjust the grille completely open (
maximum pump performance;
Position the cursor on ON if you want to operate the pump continuously;
Position the cursor on AUTO if you want to take advantage of the integrated electronic level switch; (
)
The electronic board incorporated in the pump has been programmed to guarantee 3 levels of protection:
this case the internal electronic card will activate 10 attempts to restart the pump correctly. If the pump
does not restart automatically after 10 attempts, it will switch off. In this case, to restart the pump it will be
necessary to remove the power supply plug from the socket, wait about 10 seconds before re-inserting
the plug.
if it runs without water. The electronic board will make 10 restart attempts. If there is still not enough water,
the pump will go into stand-by. To restart it, unplug and plug it back in or move the cursor between ON and
AUTO or wait for the water level to trigger the integrated electronic level switch. When the pump is taken
out of the water, the motor stops
Locked or abnormal rotor function may occur due to excessive dirt. In
protection of the motor in case of operation without water. The pump stops
it comes into operation automatically to prevent damage to the motor when the
).
);