IMPORTANT SAFETY INSTRUCTIONS FOR THE
N
INSTALLATION
G
- ATTENTION -
FOR THE SAFETY OF THE PEOPLE IT IS IMPORTANT TO FOLLOW
ALL THE INSTRUCTIONS.
FOLLOW ALL INSTALLATION INSTRUCTIONS
1° - This handbook is exclusively addressed to the specialized
personnel who knows the constructive criteria and the protection
devices against the accidents for motorized gates, doors and main doors
(follow the standards and the laws in force).
2° - The installer will have to issue to the final user a handbook in accordance
with the EN 12635.
3° - Before proceeding with the installation, the installer must forecast the
risks analysis of the final automatized closing and the safety of the
identified dangerous points (following the standards EN 12453/EN
12445).
4° - The wiring harness of the different electric components external to
the operator (for example photoelectric cells, flashlights etc.) must be
carried out according to the EN 60204-1 and the modifications to it
done in the point 5.2.2 of the EN 12453.
5° - The possible assembly of a keyboard for the manual control of the
movement must be done by positioning the keyboard so that the person
operating it does not find himself in a dangerous position; moreover, the
risk of accidental activation of the buttons must be reduced.
6° - Keep the automatism controls (push-button panel, remote control etc.)
out of the children way. The controls must be placed at a minimum
height of 1,5mt from the ground and outside the range of the mobile
parts.
7° - Before carrying out any installation, regulation or maintenance
operation of the system, take off the voltage by operating on the special
magnetothermic switch connected upstream it.
THE ALLMATIC COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for
possible damages caused by the non observance during the installation of
the safety standards and of the laws in force at present.
KEEP THESE INSTRUCTIONS WITH CARE
1° - Install a thermal magnetic switch (omnipolar, with a minimum contact
opening of 3 mm) before the control board, in case this is not provided
with it. The switch shall be guaranteed by a mark of compliance with
international standards. Such a device must be protected against
accidental closing (e.g. Installing it inside the control panel key locked
container).
2° - As far as the cable section and the cable kind are concerned, ALLMATIC
suggests to use an H05RN-F cable, with a minimum section of 1,5mm 2 ,
and to follow, In any case, the IEC 364 standard and Installation
regulations In force In your Country.
3° - Positioning of an eventual pair of photocells: The beam of the photocells
must be at an height not above the 70 cm from the ground, and, should
not be more than 20 cm away from the axis of operation of the gate
(Sliding track for sliding gate or door, and the hinges for the swing gate).
In accordance with the point 7.2.1 of EN 12445 their correct functioning
must be checked once the whole installation has been completed.
4° - In order to comply with the limits defined by the EN 12453 norm, if
the peak force is higher than the limit of 400N set by the norm, it is
necessary to use an active obstacle detection system on the whole
height of the gate (up to a maximum of 2,5m) - The photocells in this
case must be apply externally between the colums and internally for
all the race of the mobil part every 60÷70cm for all the height of the
column of the gate up to a maximum of 2,5m (EN 12445 point 7.3.2.1).
example: column height 2,2m => 6 copies of photocells - 3 internal and
3 external (better if complete of syncronism feature).
N.B.: The system must be grounded
Data described by this manual are only Indicative and ALLMATIC reserves to
modify them at any time. Install the system complying with current standards
and regulations.
6-1624804
rev.4
ITA
03/05/2017
GUARANTEE
In compliance with legislation, the manufacturer's guarantee is valid from the date
stamped on the product and is restricted to the repair or free replacement of the
parts accepted by the manufacturer as being defective due to poor quality materials
or manufacturing defects. The guarantee does not cover damage or defects caused
by external agents, faulty maintenance, overloading, natural wear and tear, choice
of incorrect product, assembly errors, or any other cause not imputable to the
manufacturer. Products that have been misused will not be guaranteed or repaired.
Printed specifications are only indicative. The manufacturer does not accept any
responsibility for range reductions or malfunctions caused by environmental
interference. The manufacturer's responsibility for damage caused to persons
resulting from accidents of any nature caused by our defective products, are only
those responsibilities that come under Italian law.