The one-way safety valve is to be operated regularly to remove lime deposits and to
-
verify that it is not blocked. Please beware of burn, because of the high temperature
of water.
The tank water can be drained through the drainage hole on the bottom of the
-
tank.
After all the pipes installed turn on the cold water inlet and hot water outlet to fill
-
the tank. When there is water normally following out from water outlet, the tank is
full. Turn off all valves and check all pipes. If any leakage, please repair.
If the inlet water pressure is less than 0.15MPa, a pressure pump should be installed
-
at the water inlet. For ensure the long safety using age of tank at the condition of
water supply hydraulic higher than 0.65MPa, a reducing valve should be mounted
at the water inlet pipe.
Filters are needed in the air inlet. If the unit is connected with ducts, filter in there
-
must be put forward to the air inlet of duct.
To fluently drain condensate water from evaporator, please install the unit at the
-
horizontal floor. Otherwise, please make sure the drain vent is at the lowest place.
Recommending the inclination angle of unit to be ground should no more than 2
degree.
Installation positions
(1)
Waste heat can be useful heat
Units can be installed near the kitchen, in the boiler-room or the garage, basically in
every room which has a large number of waste-heat so that the unit has the higher
energy efficiency even with very low outside temperatures during the winter.
(2) Hot water and dehumidification
Units can be placed in the laundry room or clothing room. When it produces hot
water it lowers the temperature and dehumidifies the room as well. The ad-
vantages can be experienced particularly in the humid season.
(3) Solar panel or external heat pump could be the second heat source
Units can work with solar panel, external heat pump, boiler or other different en-
ergy source.
NOTE:
· Choose the right path to move the unit.
· This unit complies with the relevant technical standards of electrical equipment.