Water loop connection
Please pay attention to the below points when connecting the water loop pipe:
1. Try to reduce the water loop resistance
2. Make sure there is nothing in the pipe and the water loop is smooth, check the
pipe carefully to see if there is any leak, and then pack the pipe with the insula-
tion.
3. Install the one way valve and safety valve in the water circulation system.
4. The nominal pipe wide of the field- installed sanitary installations must be se-
lected on the basis of the available water pressure and the expected pressure
drop within the piping system.
5. The water pipes may be of the flexible type. To prevent corrosion damage, make
sure that the materials used in the piping system are compatible.
6. When installing the pipe-work on the customers' site, any contamination of the
piping system must be avoided.
Water affusion and water emptying
Water Affusion:
If the unit is used for the first time or used again after emptying the tank, please make
sure that the tank is full of water before turning on the power.
Open the cold water inlet and hot water outlet.
-
Start the water affusion. When there is water normally flowing out from the hot
-
water outlet, the tank is full.
Turn off the hot water outlet valve and water affusion is finished.
-
ATTENTION: Operation without water in water tank may result in damage of aux-
iliary e-heater!
Water emptying
If the unit needs cleaning, moving etc, the tank should be emptied.
Close the cold water inlet
-
Open the hot water outlet and open the manual valve of drainpipe
-
Start the water emptying.
-
After emptying, close the manual valve.
-
: