420010311100 MULTIFLAM 700.1 - 1200.1 PR/PR TS
EN
POSITION OF IGNITION ELECTRODES
5 6 mm
NOZZLE CLEANING AND REPLACEMENT
Use only the suitable box wrench provided for this operation to remove
the nozzle, taking care to not damage the electrodes. Fit the new nozzle
with the same care.
Note: Always check the position of electrodes after having replaced the
nozzle (see illustration). A wrong position could cause ignition troubles.
29