28. Use a compressor and an air hose intended for
high-pressure nailers.
This nailer is designed to operate with air pressure
higher than that for general nailers. Therefore, use
a compressor and an air hose intended for use with
a high-pressure nailer. The main unit of this nailer,
SPECIFICATIONS
Type of power
Air pressure (Gauge)
Applicable nails
Amount of loadable nails
Size
Weight
Nail-feeding method
Hose (inside diam.)
NAIL SELECTION
Wire collated nails can be driven with this tool.
Choose a suitable nail from Fig. Nails which are not
shown in Fig. can not be driven with this tool. Nails are
linked and rolled.
Wire-collatd coil nails
Min.
6 mm
(.236")
2.5 mm
(.099")
Dimensions of nails
STANDARD ACCESSORIES
(1) Eye protector .............................................................. 1
(2) Oiler ............................................................................. 1
(3) Nose cap ..................................................................... 1
OPTIONAL ACCESSORY
Single Sequential Actuation Mechanism Kit
(Sequential Fire Parts Set, Single Shot Parts)
With the sequential fire parts,the nail is driven only
by squeezing the trigger after pushing down the
push lever.
By installing these parts, driving nails into improper
positions and unexpected firing of nails caused by
accidental operation of the push lever can be
prevented.
Piston reciprocating
12 – 23 bar (170 – 320 psi.)
ref. Fig.
150 – 300 nails (1 coil)
280 mm (L) × 338 mm (H) × 132 mm (W) (11" × 13-5/16" × 5-3/16")
2.7 kg (5.9 lbs)
Piston reciprocation
5 – 6 mm (13/64" – 15/64")
Max.
7.9 mm
(.311")
3.8 mm
(.148")
its air plug, and the air socket used to connect the
compressor and air hose are exclusively designed
for use with high-pressure parts, and cannot be
connected to standard-pressure parts.
modify the air plug and air socket. Using other
parts may result in an accident.
APPLICATIONS
Construction wooden works such as floor and wall
framing, roof decking and subflooring.
Mobile and modular home construction.
Making wooden boxes, palletes, and drums.
Packing operations in manufacturing plants, and other
types of packing and crating work in general.
PREPARATION PRIOR TO OPERATION
1. Prepare the hose
Use an air hose designed for high-pressure operation.
Be sure to use the hose provided with minimum 5
mm (13/64") inside diameter.
NOTE:
The air supply hoses must have a minimum working
pressure rating of 29.4 bar (420 psi) .
2. Check on safety
CAUTION
Unauthorized persons (including children) must be
kept away from the equipment.
Wear eye protector.
Check the retaining screws which fix the exhaust
cover, etc. for tightness.
Check the nailer for air leaks and defective or rusty
parts.
Check whether or not the push lever works correctly.
Also check whether or not any dirt has adhered to the
moving parts of the push lever.
Recheck on operational safety.
BEFORE USE
1. Check the air pressure
CAUTION
Use a compressor designed for high-pressure
operation.
The air pressure must be constantly maintained at
12 – 23 bar (170 – 320 psi.).
Adjust the air pressure between 12 to 23 bar (170 –
320 psi.) according to the diameters and length of
nails and hardness of the wood being nailed. Pay
special attention to the output pressure, capacity, and
piping on the air compressor, so that air pressure
English