Descargar Imprimir esta página

Metabo HPT NT 65MA4 S Manual De Instrucciones Y Seguridad página 22

Clavadora de acabado

Publicidad

Idiomas disponibles

Idiomas disponibles

English
without prior notice.
SERVICE AND REPAIRS
● Only service personnel trained
by metabo HPT, distributor or
employer shall repair the Nailer.
● Use
only
recommended by metabo HPT for
repair.
All quality Nailers will eventually require
servicing or replacement of parts because of
wear from normal use.
NOTE
Specifi cations are subject to change
without any obligation on the part of
metabo HPT.
Maintenance chart
ACTION
Drain air line fi lter daily.
Keep lubricator fi lled.
Clean fi lter element and blow
air through fi lter in direction
opposite to normal fl ow daily.
Clean magazine and feeder
mechanism.
Keep push lever working
properly.
Lubricate the Nailer after
nailing.
Drain air compressor daily.
22
WARNING
parts
supplied
Prevent accumulation of
moisture and dirt.
Keep the Nailer lubricated.
Prevent clogging of fi lter with
dirt.
Prevent a jam.
Promote operator safety and
effi cient Nailer operation.
Extend the Nailer life.
Keep the Nailer operated
properly.
or
WHY
HOW
Open manual petcock.
Fill with metabo HPT
pneumatic tool lubricant.
Follow manufacturer's
instructions.
Blow clean daily.
Blow clean daily.
Supply 5 – 10 drops of
lubricant into the Nailer.
Open petcock on air
compressor tank.

Publicidad

loading