Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

TIMED AUTOMATIC CLOSING MODE
Put DIP 3 in the ON position and DIP 2 in the OFF position.
In this mode, if a command is given via radio or through the "STR" input, the control unit:
- gives a steady flash of one second.
- starts the motor at the speed set on the trimmer FOR.
- opening is halted by the limit switch triggering, an obstacle being detected or the manoeuvre timing out. If additional commands
are given during opening, they have no effect.
- with the automation at a standstill or in automatic pause, when a command is given, the pause count restarts from zero each
time.
When the pause times out, the door is closed and the control unit:
- gives a steady flash of one second.
- starts the motor for one second at a reduced speed (softstar) and then at the speed set on the trimmer FOR.
- if a command is given during closing, the control unit reopens the door fully.
- closing is halted by the limit switch triggering, an obstacle being detected or the manoeuvre timing out.
Keeping the opening contact closed ("STR" terminal) for example with a timed relay, the control unit opens the door
!
and the automation remains disconnected and automatic closing is disabled until the contact is reopened (Company
Function).
STEP BY STEP MODE WITHOUT AUTOMATIC CLOSING
Put DIP 3 in the OFF position and DIP 2 in the ON position.
The step by step command sequence is OPEN-STOP-CLOSE-STOP
The opening and closing manoeuvres take place as described in the previous paragraph.
STEP BY STEP MODE WITH AUTOMATIC CLOSING
Put DIP 3 in the ON position and DIP 2 in the ON position.
The step-step logic is OPEN/STOP/CLOSE/STOP.
When the opening manoeuvre has been completed and the pause time set on the "PAU" trimmer has elapsed the control unit
effects automatic closing.
If, when the automation is closed, a radio command is given, either through the "STR" input command or the STAR pushbutton
on the board, the control unit:
- commands a one second fixed pre-flash
- it activates the motor for 1,5 second at maximum power and then at the power set with the "FOR" trimmer.
- the opening terminates when the limit switch or the mechanical stop are triggered or the manoeuvre time has elapsed.
If the automation is completely open, once the pause time has elapsed the closing manoeuvre takes place. The control unit:
- carries out a fixed two seconds pre-flash.
- it activates the motor for 1,5 second at maximum power and then at the power set with the "power" trimmer.
- The opening terminates when the limit switch or the mechanical stop are triggered or the manoeuvre time has elapsed.
DEAD MAN'S SWITCH MODE
Put DIP 3 in the OFF position and DIP 2 in the OFF position.
Hold down the STAR button located on the electronic board, the control unit opens the door until the end of opening stroke is
reached or the button is released.
Hold down the P2/RAD button located on the electronic board, the control unit closes the door until the end of closing stroke is
reached or the button is released.
The radio command has no effect. When the control unit is in this mode it is not possible to enter the programming of the radio