Press the button ("H" - Table 2 "Control panel") twice to
access the detergent and rinse aid adjustment parame-
ters.
USr
The display shows which is the first parameter of
the dispenser family:
Parameter description
Unit of measure of dispensers
(= g/l or = seconds)
Initial amount of detergent
Initial amount of rinse-aid
Amount of detergent during
the cycle
Amount of rinse-aid during
the cycle
(*) The values given in the table refer to the factory-
settings.
1. Use the Wash cycle 1 ("E" - Table 2 Control panel)
and Wash cycle 2 ("F" - Table 2 Control panel) but-
tons to select the parameter to modify.
2. Press the button ("H" - Table 2 Control panel) to mod-
ify the parameter value.
3. Press the Wash cycle 1 ("E" - Table 2 Control panel)
and Wash cycle 2 ("F" - Table 2 Control panel) but-
tons respectively to decrease/increase the value.
4. Press the button ("H" - Table 2 Control panel) to store
the set value and return to parameter selection (see
point 1).
For example, to adjust the parameter
follows:
20
DiS
dun
Value (*)
2,00 g/l
0,12 g/l
2,00 g/l
0,12 g/l
, proceed as
•
access the programming mode
•
access the dispenser family
USr
55 s
11 s
5 s
Select the parameter
•
2 s
dun
•
modify the parameter value
Press the button ("H" - Table 2 "Control panel") to store
the set value as shown in the picture.
USr
DiS
dun
DlN
37