4) TERMINAL BOARD CONNECTIONS (Fig.2)
CAUTION: Keep the low voltage connections completely
separated from the power supply connections.
Fig.3 shows the fixing and connection method of the drive condensers
whenever they are not fitted to the motor.
JP5
Single-phase power supply 120V~ ±10% 60Hz (1=L / 2=N).
1-2
For connection to the mains use a multiple-pole cable with a minimum cross
section of 3x1.5mm
2
(16AWG) of the type indicated in the above-mentioned
standard (UL1015).
JP3
5-6
120V~ 40W max. blinker connection.
7-8-9
Motor M1 connection - 8 common, 7-9 start.
10-11-12
Motor M2(r) connection - 11 common, 10-12 start.
JP4
13-14
Open-close button and key switch (N.O.).
13-15
Stop button (N.C.). If unused, leave bridged.
13-16
Photocell or pneumatic edge input (N.C.). If unused, leave
bridged.
17-18
24V 3W max. gate open warning light.
18-19
24V~ 0.25A max. (6VA) output (for supplying photocell or
other device).
20-21
Antenna input for radio-receiver board (20 signal - 21 braid).
22
Common terminal (equivalent to terminal 13).
JP1
Radio-receiver board connector 1-2 channels.
5) FUNCTIONS
DL1: Power-on Led
It is switched on when the board is electrically powered.
START: four-step logic: (DIP5 OFF)
gate closed:..................................................................................it opens
during opening:............................................... it stops and activates TCA
gate open:................................................................................... it closes
during closing:.................................... it stops and does not activate TCA
after stop:.........................................................................it starts opening
START: two-step logic: (DIP5 ON)
gate closed:..................................................................................it opens
during opening:................................it stops and activats TCA (if activated)
gate open:....................................................................................it closes
during closing:..............................................................................it opens
after stop:.....................................................................................it opens
STOP: In all cases: it stops the gate until a new start command is given.
PHOT: Functions can be set with DIP-SWITCH.
Activated during closing if DIP3-ON.
Activated during opening and closing if DIP3-OFF.
SCA: Gate open indicating light.
with gate closed:...................................................................................off
when gate is opening:...........................................................................on
with gate open:.......................................................................................on
when gate is closing:.....................................................................flashing
6) DIP-SWITCH SELECTION
DIP1 Rapid closing
ON: When the position of the gate photocells is exceeded, during both
opening and closing, the gate automatically starts to close even if TCA is
activated. We recommend setting DIP3 to ON (photocells only activated
during closing).
OFF: Function not activated.
DIP2 Blocks impulses
ON: During opening, START commands are not accepted.
OFF: During opening, START commands are accepted.
DIP3 Photocells
ON: Photocells only activated during closing.
OFF: Photocells activated during opening and closing.
DIP4 Automatic closing time (TCA)
ON: Automatic closing activated (can be adjusted from 0 to 90s).
OFF: Automatic closing not activated.
DIP5 Control logic
ON: 2-step logic is activated (see start paragraph).
OFF: 4-step logic is activated (see start paragraph).
DIP6:
ATTENTION: Dip non used in mod. ARIES (always in OFF set).
10 -
ARIES UL - Ver. 03
INSTALLATION MANUAL

7) TRIMMER ADJUSTMENT

TCA This adjusts the automatic closing time, after which time the gate
automatically closes (can be adjusted from 0 to 90s).
TW This adjusts the motor working time, after which time the motor stops
(can be adjusted from 0 to 40s).
TDELAY This adjusts the closing delay time of the second motor (M2).
8) MOTOR TORQUE ADJUSTMENT
The ARIES control unit has electric torque adjustment which allows the
motor force to be adjusted.
The adjustment should be set for the minimum force required to carry out
the opening and closing strokes completely.
Adjustment is carried out by moving the connection 55 (fig.3) on the tran-
sformer sockets as described below:
Pos.TQ1 1st TORQUE (MINIMUM TORQUE)
Pos.TQ2 2nd TORQUE
Pos.TQ3 3rd TORQUE
Pos.TQ4 4th TORQUE (MAXIMUM TORQUE)
4 motor torque values can be obtained.
To gain access to the torque adjustment sockets, disconnect the mains
supply and remove the protective case "P" of the transfomer.
CAUTION: Excessive torque adjustment may jeopardise the anti-squash
safety function. On the other hand insufficient torque adjustment may not
guarantee correct opening or closing strokes.
9) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified
personnel regularly. The materials making up the set and its packing must
be disposed of according to the regulations in force.
Batteries must be properly disposed of.
WARNINGS
Correct controller operation is only ensured when the data contained
in the present manual are observed. The company is not to be held
responsible for any damage resulting from failure to observe the
installation standards and the instructions contained in the
present manual.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product
features unchanged, at any time and without undertaking to update
the present publication.

Publicidad

Tabla de contenido
loading

Tabla de contenido