9. REPLACING THE SPINDLE
For augers having a Ø 16 mm shank, the "MND1" spindle must be interchanged with the stand-
ard "MND" spindle.
Replace the spindle as follows:
9.1) Removing the "MND" spindle
– Remove the detachable guard PRM-UN and the auger (see § 4.1.1).
– Turn the fi xed guard (23) and remove from the spindle, exposing the spindle shaft (15).
– By means of the 4 mm allen key supplied with the machine, remove grubscrew (18).
– Remove circlip (16) and locating pin (17).
– Slide the spindle from the shaft (13).
9.2) Fitting the "MND1" spindle
– Slide the "MND 1" spindle onto the shaft (15). Ensure that the spindle guide (19) is correclty po-
sitioned.
– Align the hole on the shaft (13) with the corresponding holes on the spindle (20).
– Insert the locating pin (17) and fi t the circlip (16).
– Fit and tighten the grubscrew (18).
– Fit the fi xed guard (23).
– Insert and secure the auger (Ø 16 mm shank); (see § 9.3).
– Fit the detachable guard PRM-UN (see § 4.1.2).
9.3) Fitting and removing the auger on the "MND1" spindle
– Turn the emergency lever (12), align the two
grooves on the auger with the red reference line
on the end of the spindle and fully insert the auger.
– Release the emergency lever (12).
To remove the auger, turn the emergency lever
(12) extract the auger from the spindle.
10. RETURN TO CEMBRE FOR OVERHAUL
In the case of a breakdown contact our Area Agent who will advise you on the problem and
give you the necessary instructions on how to dispatch the tool to our nearest service Centre;
if possible, attach a copy of the Test Certifi cate supplied by CEMBRE together with the tool or
fi ll in and attach the form available in the "ASSISTANCE" section of the CEMBRE website.