Descargar Imprimir esta página

Dräger X-act 7000 Instrucciones De Uso página 20

Ocultar thumbs Ver también para X-act 7000:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
en
|
Maintenance
Once slight resistance is noticeable, do not push any further. The device
will pull in the Dräger MicroTubes itself.
Once the device has pulled in the Dräger MicroTubes completely, the
name of the Dräger MicroTubes will appear on the display: in this
example, Benzene. The number of remaining measurements for the
MicroTubes in question will also be shown, along with the batch number
and concentration range.
3. Start measurement (Graphic D/3b).
● Press OK.
Once the measurement is running, the information Measurement
running will appear on the display. The measurement may take several
seconds or minutes.
The measurement has been successfully completed once the LED on
the display lights up green. The results are then shown on the display.
The measurements are numbered and the number of the measurement
in question is shown in the upper area of the display. In this example, it
is measurement 10 of 10.
4. The following steps may now be taken:
● Assign result to a measurement location (Graphic D/3c)
● Carry out further measurements (Graphic D/3d)
● Eject or change Dräger MicroTubes
● Turn off device after the measurement: Press and hold OK for 3
seconds.
4.3.3
Save result and measurement location
The user has the option of assigning the measurement result to a measurement
location once the measurement has been completed. This is only possible once
the location has already been saved to the device using CC-Vision software.
Assign the measurement result as follows:
For further information see: "Operation and navigation", page 16.
1. Call up the list with the previously defined locations in the Results display
(Graphic D/9).
2. Select the Measurement location.
3. Confirm the selection by pressing OK.
20
4.3.4
Carry out further measurements
After the measurement, further measurements may be carried out until all
Dräger MicroTubes have been used. It is possible to carry out 10
measurements per MicroTubes.
1. Press OK:
 The user returns to the Start display.
2. Press OK again:
 Another measurement may be carried out.
4.3.5
Eject or change Dräger MicroTubes
If all Dräger MicroTubes have been used (0/10 will appear at the top of the
display) or another substance needs to be measured, the Dräger MicroTubes
will need to be changed.
1. Navigate to the main screen (Graphic D/2).
2. Press UP (Graphic D/2c)
 The Dräger MicroTubes are ejected.
3. New Dräger MicroTubes may be inserted. For further information see:
"Carry out measurement", page 19.
4.3.6
Turn off X-act 7000
1. Press and hold OK for 3 seconds until the countdown has run out.
5
Maintenance
5.1
Maintenance intervals
NOTICE
The service recommendation appears 1 year after commissioning or 2
years after production of the X-act 7000 at the latest.
The device can still be used if this deadline expires, however there will be a
greater risk of inaccurate measurement results.
► Dräger strongly recommends servicing the device every 12 months.
Instructions for use
®
|
X-act
7000

Publicidad

loading

Este manual también es adecuado para:

Mmg 0001