Descargar Imprimir esta página

Panasonic EYFLF1XA Manual De Instrucciones página 14

Ocultar thumbs Ver también para EYFLF1XA:

Publicidad

Idiomas disponibles

Idiomas disponibles

[Fig.20]
How to set
EN
[Step 1]
Select Torque Setting Stage (1-40)
Torque Setting Stage:
Select referring to index chart
[Fig. 22]
Snug Tight Detection setting: L1
Select Flush Detection Level (L1-L7 / Use only when final torque can't be increased by
[Step 2]
Torque Setting Stage change)
* Increase Flush Detection Level one by one. There is a risk of over torque when Flush Detection Level is increased.
Torque Setting Stage:
* Select referring to index chart
Snug Tight Detection setting:
Change from L1 to L2
* Please reset Torque Setting Stage if it's
increased in Step1.
[Step 3]
Fine-tune Torque Setting Stage to meet target torque and complete setting
Trial fastening
Check torque
Not OK
Change Torque
Setting Stage
Trial fastening
Check torque
Not OK
Change Snug Tight
Detection setting
L2→L3~L7
‒ 14 ‒
Final torque meets target torque
OK
Even though changing Torque Setting Stage,
final torque can't be increased.
(Fastener doesn't seat correctly)
Not OK
Final torque is above lower tolerance limit
OK
Flush!
Final torque can't be increased.
(Fastener doesn't seat correctly)
Setting
complete
Move to Step 2