Descargar Imprimir esta página

Panasonic EYFLF1XA Manual De Instrucciones página 21

Ocultar thumbs Ver también para EYFLF1XA:

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Press the OK button to accept the new
setting.
[EYFLF]
Rundown error detecting function
The rundown error detecting function caus-
es a red indicator to flash if work ends more
quickly than a set time, for example due to
retightening of a previously tightened fastener
or binding of the screw's thread.
1. Set the tool to setting configuration mode.
(See page 19.)
2. Press the B button twice.
The rundown error detecting function set-
ting value will be displayed.
[Fig.21]
3. Press the
and
time as desired.
Buttons
Display
4. Press the OK button to accept the select-
ed setting.
When the cross thread reduction function
is ON, the set time will be counted after
the tool operates in reverse for approxi-
mately 360°.
Radio signal range limitation
function on/off setting
1. Set the tool to configuration mode.
(See page 19.)
2. Press the C button.
• The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and
off.
[Fig.22]
3. Press the C button twice.
• Radio signal range limitation function
ON/OFF setting value will be displayed.
[Fig.23]
4. Press the
and
signal range limitation function ON/OFF.
buttons to change the
Seconds
30
3
1
0.1
0
OFF
buttons to set radio
Radio signal
Display
range limitation
function mode
C0
OFF
C1
ON
5. Press the OK button to accept the new
setting.
NOTE:
• For more information about how to regis-
ter the tool and Assembly Qualifier, see
the Assembly Qualifier instruction man-
ual.
Factory settings
• Radio signal range limitation function
setting: C0 (OFF)
One-way and two-way
Communication function setting
1. Set the tool to configuration mode.
(See page 19.)
2. Press the C button four times.
• The control panel will begin flashing.
Display: The letter "q1" flashes on and
off.
[Fig.24]
3. Press the OK button to accept the new
setting.
Display
q0
One-way Communication
q1
Two-way Communication
NOTE:
• Panasonic Assembly Qualifier Model
No.EYFR02 : One-way communication
only
Factory settings
• One-way and two-way communication
function setting: q0 (One-way commu-
nication)
Two-way Communication displays
• When the tool is in "Two-way Communica-
tion Stand by" mode, Tightening confirma-
tion lamp blinks in Orange to indicate.
‒ 21 ‒
Status
Tool is operational
in the absence of
communications
with the Assembly
Qualifier.
Tool is not operational
in the absence of
communications
with the Assembly
Qualifier.
Function
EN

Publicidad

loading