Descargar Imprimir esta página

WIKA PEW-1 Serie Manual De Instrucciones página 20

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Commissioning, operation
4.5.5 Pressure change (slope), rising
Calculates the pressure change in % / minute
(P1 - P0) / t
EN
P0
=
Initial pressure
P1
=
Pressure recorded by Measuring interval t
t
=
Adjusted Measuring in minutes
Example: Pressure rises from 3 to 5 bar based on a measuring interval of 5 minutes: → (5 - 3) / 5 = 0,4 bar / minute
Calculated
pressure change
Alarm limit
Sensor measured
value
20
Alarm triggered Alarm switched off
Measuring interval
WIKA operating instructions, models PEW-1000 and PEW-1200
Time