Descargar Imprimir esta página

haacon 64604 Manual De Instrucciones página 7

Ocultar thumbs Ver también para 64604:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
cE conformity
The declaration of conformity is only valid if cranes including
the lifting gear and quiver are used, which are an integral part
of the delivery by haacon. The quivers must be attached in
accordance with the instructions in this manual.
5. GENERAL
The swivel jib crane is a aluminium construction with variable over-
hang. It is inserted into a box column, which can be attached to the
ground or to the basin edge, and serves for lifting and lowering, as well
as swivelling loads, predominantly in sewage treatment plants.
Manually operated chain hoists or galvanised respectively stainless
steel rope winches are used as hoisting gears.
The crane complies with lifting class H1 from DIN 15018 and is suited
for a total of load changes < 2 x 10
6. BoX coLumN FASTENING
The box columns must be attached sufficiently and according to the
following regulations.
The operator and/or the company assigned by him for carrying out
the mounting are responsible for this. The correct construction of the
mounting must be confirmed (e.g. with mounting protocol).
6.1 Ground, wall mounting with shear connectors
Basis for dimensioning the anchorage is the „Guideline for the Europe-
an Technical Approval of Metal Anchors for use in Concrete", Appendix
C, technology A, for bonded anchors. They are subject on-site to the
responsibility of an engineer having experience of anchorages and
concrete construction.
The following must be observed:
– Impacts and vibrations are inadmissible.
– Anchors are approved for use indoors and for use outdoors, if
no particularly aggressive conditions are present, e.g.:
– Spraying zone of sea water, constant, alternating immersion in
sea water
– Chloric atmospheres, e.g. in indoor swimming pools
– Extreme chemical contaminations, e.g. such as
– in flue gas desulphurating plants
– Anchors may be set in dry and wet concrete, however not in
boreholes filled with water
– Overhead assembly is inadmissible
– The temperature range for use of the anchorages is enc-
losed: 40 °C to +50 °C (max. long-term temperature) to
+80 °C (max. short-term temperature).
The shear connectors must be selected with consideration to the lar-
gest permissible load, with the greatest possible overhang of the crane
for the shear connector system according to approval (ETA-05/0231:
MKT V A4).
Concrete/Underground
– unripped concrete (pressure zone)
– C20/24 (B25) ≤ Concrete strength class ≤ C50/60 after EN
206:2000-12
– Normal or without reinforcement, without edge reinforcement
– Perfect compression, no significant cavities
– Minimum concrete thickness: 120 mm
Geometrical characteristic values
– Minimum distance to each concrete edge: 60 mm
– Minimum distance between the shear connectors according to re-
quirements of the mounting holes and/or after drawing (s. point 12)
094160_o_de_gb_fr_es_pt_it_nl_drehkr_s
4
.
haacon hebetechnik gmbh – Telefon +49 (0) 9375 - 84-0 – Fax +49 (0) 9375 - 8466
Mounting and anchor characteristic values
Product information
Composite anchor V 4A M10
Approval ETA-05/0231: MKT V 4A
Mounting and anchor characteristic values
Thread
ø
Drill hole diameter
d
0
Hole depth
h
(1)
0
Anchorage depth
h
ef
Torque
T
inst
Wrench size
SW
Minimum fixture thickness
h
Minimum distance to each
c
concrete edge
Mounting and anchor characteristic values
Anchor size
M10 M12 M16
Drill diameter
d
=
[mm]
0
Cutting Ø
d
[mm] 12,5 14,5
cut
Hole depth
h
[mm]
0
Brush Ø
D
[mm]
Fixing torque
T
=
[Nm]
inst
Wire brush
Curing time up to applying the load
Minimum curing time [minutes]
Base material
temperature [°C]
Dry concrete
+ 35
10
+ 30
10
+ 20
20
+ 10
60
+ 5
60
0
300
- 5
300
The valid approval as well as a mounting protocol can be downloaded
in the Internet from:
www.mkt-duebel.de
– download - Zulassungen/approvals - Verbundanker/chemical
anchor
– download - Arbeitshilfen - Montageprotokoll
M10
M16
= 10 mm
= 16 mm
= 12 mm
= 18 mm
= 90 mm
= 125 mm
= 90 mm
= 125 mm
= 12 Nm
= 45 Nm
= 17 mm
= 24 mm
≥ 120 mm
≥ 175 mm
≥ 60 mm
≥ 100 mm
M20
M24
12
14
18
25
28
18,5
25,5
28,5
90
110
125
170
210
13
16
20
27
30
12
20
45
100
150
Wet concrete
20
20
40
120
120
600
600
7
GB

Publicidad

loading

Productos relacionados para haacon 64604

Este manual también es adecuado para:

64609