3.6.10. Activation/deactivation of the pH measurement (option)
Menu
pH regulation
Mode
XXX
3.6.11. Setting the salinity
Menu
Electrolysis
Salinity
XX
3.6.12. Boost mode
Boost mode :
- sets the production setpoint up to 125 %, for a fixed period.
- can be manually stopped at any time.
- can be used when chlorine is urgently needed.
I
Boost mode cannot replace a conventional shock treatment in cases of water not fit for bathing.
• If the Boost mode is restarted manually while it is already running, the Boost mode resets for the duration displayed.
• Boost mode cannot be switched on if an alarm has been triggered. After having resolved and dismissed this alarm,
wait a few moments in order to be able to activate the Boost mode.
• When the Boost mode ends or is manually stopped, production continues according to the initial setpoint.
• Boost mode continues after powering off the electronics unit.
Operation with a cover sensor :
• Boost mode cannot be switched on with the cover shut.
• If the cover is closed with Boost mode switched on, Boost mode automatically stops.
Possible
Menu
settings
• 12 h
Electrolysis
• 24 h
Boost
3.6.13. Calibrating the probes : important advance information
→ The original pH probe is already calibrated. It is therefore not necessary to carry out calibration of the pH probe
when putting the equipment into service for the first time.
I
However, it is imperative to carry out a calibration of the pH probe at the beginning of each season when
returning to service, and after each probe replacement.
3.6.14. Calibrating the pH probe
1) Open the pH 7 and pH 10 calibration solutions (use only single-use calibration solutions).
2) Turn off the filtration (and therefore the electronics unit).
3) If the probe is already installed :
Possibles settings
• ON
• OFF
•
NS: 3200 ppm
•
LS: 1500 ppm
Default
Switching on
setting
Automatic as soon as the
24 h
duration setting is confirmed.
Possible settings
(specific display variants)
Default setting
ON
Default setting
Operation indicator
Bo 12 h or Bo 24 h
Boost 12 h or Boost 24 h
NS
Switching off
Press on
.
10