IMMEDIATE
MESSAGE
AUTOMATIC
DISPLAYED
ACTION
/ FAULT
Stopping
DETECTED
production
Alarm
Yes
Low Salt
3.8. Further information
Menu
Soft Version
MASTER: XX.XX.XX
Soft Version
SLAVE:
XX.XX.XX
ID Code:
XXXXXXXX
Serial Number:
XXXX-XXXXXX-XXX
MAC Address:
XXXXXXXXXXXX
MCU Temperature:
XX°F
CAUSE
Salt level less than
2500 ppm (or 1200
ppm
if
Low
Salt
equipment).
Insufficient amount of
water in the filtration
circuit.
MAC address for Bluetooth connection
Internal temperature in the electronics unit
CHECKS AND REMEDIES
• Check the salt levels in the pool using a
recent testing kit.
• Top up with salt if necessary, so as to
obtain a salt level of 5000 ppm (or 2500
ppm for Low Salt equipment).
• Check that the pipe at the level of the
salt sensor is completely filled with
water.
• If necessary, top up the water in the
pool.
Meaning
Control board program
Power card program
Configuration code
Serial number
OPTION TO
DEACTIVATE
VIA THE
MENU
«
Parameters -
»
Alarms
Yes
15