1
120 ± 12
V.A.C.
5
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
1
L1
2
Ground
3
Neutral Side
4
Round Grounding Prong
5
Neutral
Figure 23
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT. DO NOT OVERLOAD
CIRCUITS!
Do not operate both a washer and gas dryer on the
same circuit. Use separately fused 15 Amp circuits.
WARNING
To reduce the risk of electric shock or fire,
DO NOT use an extension cord or an
adapter to connect the washer to the
electrical power source.
801539
3
2
0
V.A.C.
120 + 12
V.A.C.
4
D799I
W031
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electric Dryer
(120/240 Volt, 60 Hertz, 3-Wire Installation)
(120/208 Volt, 60 Hertz, 3-Wire Installation)*
*Alternative Heating Element Required
NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.
WARNING
To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of the
National Electrical Code ANSI/NFPA 70 or
the Canadian Electrical Code, CSA C22.1,
and such local regulations as might apply.
It is the customer's responsibility to have
the wiring and fuses checked by a qualified
electrician to make sure the laundry room
has adequate electrical power to operate
the dryer.
Grounding and Wiring Instructions
The dryer must be connected to a grounded
metal, permanent wiring system; or an
equipment-grounding conductor must be run
with the circuit conductors and connected to the
equipment-grounding terminal or lead on the
dryer.
The dryer has its own terminal block that must be
connected to a separate branch, 60 Hertz, single
phase circuit, AC (alternating current) circuit,
fused at 30 Amperes (the circuit must be fused
on both sides of the line). ELECTRICAL
SERVICE FOR THE DRYER SHOULD BE
OF MAXIMUM RATED VOLTAGE LISTED
ON THE NAMEPLATE. DO NOT
CONNECT DRYER TO 110, 115, OR
120 VOLT CIRCUIT. Heating elements are
available for field installation in dryers which are
to be connected to electrical service of different
voltage than that listed on nameplate, such as
208 Volt.
Installation
W035
29