1
120 ± 12
V.A.C.
5
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE
EFFECTIVELY GROUNDED CIRCUIT
1
L1
2
Ground
3
Neutral Side
4
Round Grounding Prong
5
Neutral
Figure 30
801539
3
2
0
V.A.C.
120 + 12
V.A.C.
4
D799I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Grounding Instructions
The dryer must be grounded. In the event of
malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a
path of least resistance for electric current. The
dryer is equipped with a cord having an
equipment-grounding conductor and a three-
prong grounding plug. The plug must be plugged
into an appropriate outlet that is properly
installed and grounded in accordance with all
local codes and ordinances.
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the dryer is properly
grounded.
DO NOT modify the plug provided with the
dryer unit – if it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
If the laundry room's electrical supply does not
meet the above specifications and/or if you are
not sure the laundry room has an effective
ground, have a qualified electrician or your local
electrical utility company check it and correct
any problems.
Installation
W038
37