Descaling The Electric Booster Element; Protective Anode; Valves; Replacing The Power Cable - Stiebel Eltron Accelera 220 E Funcionamiento E Instalación

Calentador de agua con bomba eléctrica de calor
Ocultar thumbs Ver también para Accelera 220 E:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
Maintenance and cleaning

15.5 Descaling the electric booster element

Only descale the fl ange of the electric booster element after re-
moving it, and never treat the interior of the DHW tank and the im-
pressed current anode with descaling agents. The electric booster
element is screwed into the appliance at a central point at the top.
1
1 Electric booster element with protective anode

15.6 Protective anode

The fl ange of the electric booster element is equipped with a
protective anode that protects the appliance from corrosion while
it is connected to the power supply. The protective anode is a
maintenance-free impressed current anode.
If a fault code in the display indicates that the protective anode is
faulty, proceed as follows:
 Remove the controller of the electric booster element.
 Check the protective anode connector and its wiring.
 Refi t the controller of the electric booster element.

15.7 Valves

Regularly check the system's valves (safety valve, pressure reduc-
ing valve, drain valve, vacuum breaker, mixing valve), to ensure the
operational reliability of the appliance. The amount of lime-scale
deposits depends on local water quality.
 Check all valves in the system and remove lime-scale
deposits.
 Replace the valves if necessary.
 Check the function of the valves.

15.8 Replacing the power cable

WARNING Electrocution
If the power cable is faulty, replace it with a new one.
The power cable should only be replaced by a qualifi ed
contractor. Please contact Stiebel Eltron at 800-582-8423
www.stiebel-eltron-usa.com

15.9 Fitting the casing ring

WARNING Electrocution
 Reconnect the ground wire to the casing ring.
 Fit the upper casing ring. The casing ring overlaps along the
joint. A tab on one end clips into the recess on the other end
of the casing ring.
 Secure the casing ring with fi xing screws.
 Fit the pipe collar of the condensate drain and the conden-
sate drain bend.

15.10 Fitting the appliance cover

WARNING Electrocution
 Reconnect the ground wire to the appliance cover.
 Place the lid back on the appliance top.
 Connect the ground cable to the signed ground terminal.
 Connect the cable linking the control with the appliance ECB
to the back of the panel.
 Insert the control panel.
 Secure the appliance cover and the control panel using the
screw at the top of the control panel.
Accelera® 220-300 E |
29

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Accelera 300 e

Tabla de contenido