Connecting the inverter
7
Connecting the inverter
!
WARNING!
Never connect more than one consumer device to the inverter. The
connection of more than one device must be executed by an electrically
qualified person complying with the local requirements for protection
against electric shock.
A
NOTICE!
• Incorrect polarity will blow an internal fuse which has to be replaced
by the Dometic service. Additionally the electronics may be dam-
aged.
• Make sure that the inverter is operated with the following voltage
only:
– DSP212, DSP412: 12 Vg
– DSP224, DSP424: 24 Vg
➤ Connect the inverter as shown:
– Connecting the battery:
DSP212, DSP224: fig. 5, page 5
DSP412, DSP424: fig. 6, page 5
– Connecting load: fig. 7, page 6
Connect external switch to turn device on and off (DSP412, DSP424 only)
I
NOTE
The inverter is switched on when the external or the main switch
(fig. 2 1, page 3) is switch on. If the inverter shall be controlled via
external switch only, the main switch has to be switch to position "0".
➤ Connect the external switch as shown (fig. 8, page 6).
8
Using the inverter
!
CAUTION!
When connecting the load observe the applicable regulations.
16
DSP 212, DSP 224, DSP 412, DSP 424